*Types Of
Cement:-
1. 1.Ordinary Portland Cement (OPC):-
· OPC -43 (IS:8112-1989)
· OPC -53 (IS:12269-1987)
· IST (Initial Setting Time)-30 minutes
· FST (Final Setting Time)-600 minutes
· OPC -33 used in small structures
· OPC -43 used in normal structures like houses etc.
· OPC -53 uses in large structures/precast structures like Bridges, Griders etc.
2. 2. Rapid Hardening Cement(IS:8041):-
· 10% more cost than OPC.
· Not used in mass concrete & it produce Large Shrinkage.
· RHC attains same strength in 1 day which an OPC attains in 3 days with same w/c (water content).
· It is suitable for repair of roads, bridges etc.
· IST-10 minutes.
· FST-10 hours.
· Compressive Strength for one day is 16 N/mm².
3. 3. Extra Rapid Hardening Cement:-
· 1st day strength – 25% More than OPC.
· 7th day strength – 20% More than OPC.
· Used in cold regions for repair works.
4. 4. High Alumina Cement(IS:6452):-
· Acid and Sulphate attack is less.
· Composition- (Bauxite-40%, Lime-40%, Iron Oxide-15%, Magnesia-5%).
· IST-3.5-4 hours.
· FST-5-5.5 hours
· It is used for refractory concrete, industries & used widely in Precasting.
· Particularly suitable to sea & under water work.
5. 5.Low
Heat Portland Cement:-
· IST-1 hour.
· FST-10 hours.
· Acid & Sulphate attack is less.
· It is used in mass concrete work.
· Rate of development strength is low but ultimate strength is sam,e.
· Heat of Hydration 272-314 KJ/Kg.
6. 6.Quick
Setting Cement:-
· It is also called as Fine Grounded OPC.
· IST-5 minutes.
· FST-30 minutes.
· Used in under water concreting.
7. 7.Coloured
Portland Cement and White Cement(IS:8042):-
·
The cement which is free from
iron oxide (Fe2O3).
·
Added White Chalk and China Clay.
·
These are used for making
Terrazzo Flooring, ornamental works & casting stones.
·
Hunter scale is used for checking
the whiteness of cement.
·
90% strength attains with the help of Sodium
Alumino Ferrate.
·
5-10% colouring pigment added
before grinding.
8. 8. Super
Sulphated Portland Cement:-
· It is resistant to sulphate attack. And highly resistant to sea water.
· It should not be used with any admixture.
9. 9.Portland
Pozzolana Cement (IS:1489 part-1):-
· It is used in marine work.
· Free lime is removed hence , resistance to chemical attack increases.
· Pozzolana increases impermeability & water retaining capacity of concrete.
· Pozzolana has no cementing property in itself but when it combines with lime, it provides a stable lime pozzolana compound which has cementious property.
· The addition of pozzolana to concrete results in :-
a)
Improvement in durability by
reducing permeability.
b)
Increase in workability of
concrete.
c)
Reduction in shrinkage.
d)
Reduction in segregation &
bleeding of concrete.
10.
Portland Slag Cement:-
· High Sulphate Resistant.
· It is used in mass concreting.
11.Water
Repellant or Hydrophobic Cement:-
· Suitable for basement & making water tight structures.
12.Air Entraining Cement:-
· Small amount (0.1%) by weight of an air entraining agent.
Minimum
Specified Strength in N/mm² |
||||
Type/Days |
1 Day |
3 Days |
7 Days |
28 Days |
OPC (33
grade) |
---------- |
16 |
22 |
33 |
Portland Pozzolana |
-------- |
------- |
22 |
33 |
Low
Heat Portland |
-------- |
10 |
16 |
33 |
*Types Of
Cement Tests:-
Physical
Tests:-
1. 1.Fineness Test:-
· With increase in fineness, the early development of strength is enchanced but the ultimate strength is not affected.
· Setting time decrease with increase in the fineness.
2. 2. Consistency :-
· It is about 30% generally.
· It is the percentage of water required for the cement paste.
· The viscosity of which will be such that Vicat’s plunger penetrates upto 5 to 7 mm from bottom (33 to 35 mm from top) of Vicat’s mould.
*Diameter
length & shape of Vicat apparatus for different test.
S.No. |
Types of Test |
Diameter or size |
Length |
Shape |
1. |
Initial setting time |
1 mm of square needle |
Upto 50 mm & 40mm |
|
2. |
Final setting time |
5 mm |
Upto 50 mm & 40mm |
|
3. |
Consistency |
10 mm |
Upto 50 mm & 40mm |
Solid circular |
3. 3. Initial
& Final Setting Time:-
Initial
Setting Time |
Final
Setting Time |
·
It is possible to remix cement paste during this period. |
·
Annular collar replaces square needle. |
·
300 gm cement + 0.85 P of water (consistency) |
·
Needle makes an impression but collar fails to do so. |
·
1 mm2 square needle penetrates by 33-35 from top. |
|
·
IST for OPC, RHC is 30 minutes. |
·
FST for OPC, RHC – 10 hours. |
·
IST for low heat
cement – 1 hour. |
·
FST for LHC – 10 hours. |
·
IST for High alumina
cement – (3.5-4) hours. |
·
FST for High alumina cement – (5-5.5) hours. |
4. 4.Soundness
Test:-
· Soundness test is done to detect change in volume after setting.
· Two methods are adopted for soundness test. 1. Le-Chatelier’s method, 2. Auto clave Test
Le-Chatelier’s
method |
Auto clave Test |
·
Measures soundness due to lime. |
·
Measures soundness due to lime and magnesia. |
·
100 gm of cement +0.78 P
(consistency) |
·
100 gm of cement +0.78 P
(consistency) |
·
Result is given in “mm”. |
·
Result is given in “%age”. |
*Le-Chatelier’s
method:-
· Both the ends of mould are covered with the glass plates.
· And the mould is filled with the cement paste of 0.78 P consistency.
· Two strips are inserted in the cement paste.
· After 24 hours measures the gap b\w the strips.
· Let the gap is L1.
· And after it the cylinder is dipped in the boiled water for 3 hours.
· And cool down it for ½ hour.
· And then again measure the gap b\w the strips.
· Let the gap is L2.
· Then the Soundness value is (L2-L1).
· The soundness value for the OPC, RHC and low heat cement is ≯10mm.
· The soundness value for High Alumina and supersulphated cement is 5mm.
*Auto
clave Test:-
· Fill it with cement paste of consistency 0.78 P.
· After 24 hours measure the length of the mould suppose it is L1.
· Now Steam saturation of the mould is done with 1.2 N/mm² to 2.1 N/mm² for 30 minutes.
· After this process the mould is dipped in water of temperature 90° C for ½ hour.
· And cool down it for ½ hour.
· And after it again measures the length of mould suppose it is L2.
· Then the soundness value is (L2-L1).
· For any type of cement in auto clave test the soundness value is ≯.8%.
5. 5.Strength
Test:-
· Heat of Hydration is measured by Calorimeter.
· Specific gravity is measured by the Le-Chatelier’s flask.
· Specific Gravity of OPC is 3.15.
Time |
OPC 33 N/mm² |
OPC 43 N/mm² |
OPC 53 N/mm² |
LHC N/mm² |
3
days |
16 |
23 |
27 |
10 |
7 days |
22 |
33 |
37 |
16 |
28 days |
33 |
43 |
53 |
35 |